Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
2.
Indoor Air ; 32(10): e13118, 2022 Oct.
Article in English | MEDLINE | ID: covidwho-2088231

ABSTRACT

SARS-CoV-2 has been detected both in air and on surfaces, but questions remain about the patient-specific and environmental factors affecting virus transmission. Additionally, more detailed information on viral sampling of the air is needed. This prospective cohort study (N = 56) presents results from 258 air and 252 surface samples from the surroundings of 23 hospitalized and eight home-treated COVID-19 index patients between July 2020 and March 2021 and compares the results between the measured environments and patient factors. Additionally, epidemiological and experimental investigations were performed. The proportions of qRT-PCR-positive air (10.7% hospital/17.6% homes) and surface samples (8.8%/12.9%) showed statistical similarity in hospital and homes. Significant SARS-CoV-2 air contamination was observed in a large (655.25 m3 ) mechanically ventilated (1.67 air changes per hour, 32.4-421 L/s/patient) patient hall even with only two patients present. All positive air samples were obtained in the absence of aerosol-generating procedures. In four cases, positive environmental samples were detected after the patients had developed a neutralizing IgG response. SARS-CoV-2 RNA was detected in the following particle sizes: 0.65-4.7 µm, 7.0-12.0 µm, >10 µm, and <100 µm. Appropriate infection control against airborne and surface transmission routes is needed in both environments, even after antibody production has begun.


Subject(s)
Air Pollution, Indoor , COVID-19 , Humans , SARS-CoV-2 , COVID-19/epidemiology , RNA, Viral , Prospective Studies , Respiratory Aerosols and Droplets
3.
Eur Arch Otorhinolaryngol ; 279(2): 825-834, 2022 Feb.
Article in English | MEDLINE | ID: covidwho-1661679

ABSTRACT

OBJECTIVE: COVID-19 spreads through aerosols produced in coughing, talking, exhalation, and also in some surgical procedures. Use of CO2 laser in laryngeal surgery has been observed to generate aerosols, however, other techniques, such cold dissection and microdebrider, have not been sufficiently investigated. We aimed to assess whether aerosol generation occurs during laryngeal operations and the effect of different instruments on aerosol production. METHODS: We measured particle concentration generated during surgeries with an Optical Particle Sizer. Cough data collected from volunteers and aerosol concentration of an empty operating room served as references. Aerosol concentrations when using different techniques and equipment were compared with references as well as with each other. RESULTS: Thirteen laryngological surgeries were evaluated. The highest total aerosol concentrations were observed when using CO2 laser and these were significantly higher than the concentrations when using microdebrider or cold dissection (p < 0.0001, p < 0.0001) or in the background or during coughing (p < 0.0001, p < 0.0001). In contrast, neither microdebrider nor cold dissection produced significant concentrations of aerosol compared with coughing (p = 0.146, p = 0.753). In comparing all three techniques, microdebrider produced the least aerosol particles. CONCLUSIONS: Microdebrider and cold dissection can be regarded as aerosol-generating relative to background reference concentrations, but they should not be considered as high-risk aerosol-generating procedures, as the concentrations are low and do not exceed those of coughing. A step-down algorithm from CO2 laser to cold instruments and microdebrider is recommended to lower the risk of airborne infections among medical staff.


Subject(s)
COVID-19 , Lasers, Gas , Aerosols , Carbon Dioxide , Humans , SARS-CoV-2
4.
Acta Anaesthesiol Scand ; 66(4): 463-472, 2022 Apr.
Article in English | MEDLINE | ID: covidwho-1596588

ABSTRACT

BACKGROUND: Intubation, laryngoscopy, and extubation are considered highly aerosol-generating procedures, and additional safety protocols are used during COVID-19 pandemic in these procedures. However, previous studies are mainly experimental and have neither analyzed staff exposure to aerosol generation in the real-life operating room environment nor compared the exposure to aerosol concentrations generated during normal patient care. To assess operational staff exposure to potentially infectious particle generation during general anesthesia, we measured particle concentration and size distribution with patients undergoing surgery with Optical Particle Sizer. METHODS: A single-center observative multidisciplinary clinical study in Helsinki University Hospital with 39 adult patients who underwent general anesthesia with tracheal intubation. Mean particle concentrations during different anesthesia procedures were statistically compared with cough control data collected from 37 volunteers to assess the differences in particle generation. RESULTS: This study measured 25 preoxygenations, 30 mask ventilations, 28 intubations, and 24 extubations. The highest total aerosol concentration of 1153 particles (p)/cm³ was observed during mask ventilation. Preoxygenations, mask ventilations, and extubations as well as uncomplicated intubations generated mean aerosol concentrations statistically comparable to coughing. It is noteworthy that difficult intubation generated significantly fewer aerosols than either uncomplicated intubation (p = .007) or coughing (p = 0.006). CONCLUSIONS: Anesthesia induction generates mainly small (<1 µm) aerosol particles. Based on our results, general anesthesia procedures are not highly aerosol-generating compared with coughing. Thus, their definition as high-risk aerosol-generating procedures should be re-evaluated due to comparable exposures during normal patient care. IMPLICATION STATEMENT: The list of aerosol-generating procedures guides the use of protective equipments in hospitals. Intubation is listed as a high-risk aerosol-generating procedure, however, aerosol generation has not been measured thoroughly. We measured aerosol generation during general anesthesia. None of the general anesthesia procedures generated statistically more aerosols than coughing and thus should not be considered as higher risk compared to normal respiratory activities.


Subject(s)
COVID-19 , Cough , Adult , Aerosols , Anesthesia, General , Humans , Pandemics
SELECTION OF CITATIONS
SEARCH DETAIL